Skip to main content
Skip to main content
Exterior Pro Materials
MAC Metal ArchitecturalVersa Collection

Versa

Versa by MAC Metal Architectural brings dynamism and stature to any facade through its wide 12" profile that creates large, smooth, continuous surfaces with no visible screws or joints along the panel's full length. Install it horizontally, vertically, or diagonally — the same hidden-fastener clip system accommodates all orientations and allows individual panel replacement without disturbing adjacent panels. Custom lengths to 12 ft, available in 9 colours with the TEXTURAL III & IV matte paint system, and offered with a vented soffit version providing 4.594 sq.in. of ventilation per linear foot.

1" depth (25.4 mm) · 1.32 lb/ft² (24g)3830.4 Pa / 80 psf @ 16" o.c. wind9 colours

Available Colours

9
Versa - Anthracite

Anthracite

Signature Collection

Signature Collection(3)

Inspiration Collection(6)

Colours shown are approximate representations only and may appear differently on screen than the actual product. Request a physical sample before making your final decision.

Profiles & Specifications

Versa - Versa profile
VSVersa

Pre-painted galvanized steel wall panel with no visible screws or joints along the entire panel length. Wide 12" profile creates large, smooth, continuous surfaces with a bold architectural presence. Custom lengths up to 12 ft (not recommended beyond). The serrated clip system allows individual panel replacement in case of damage.

LengthCustom up to 12' (3658 mm) — assorted according to plans and specifications
Height / Width12" coverage (304.8 mm)
Thickness1" depth (25.4 mm)
Panel Weight1.32 lb/ft² (0.60 kg/m²) — 24g | 1.65 lb/ft² (0.75 kg/m²) — 22g
Panels/Box50 panels/box
CoverageDepends on custom length ordered
Wind Resistance3830.4 Pa (80 psf) @ 16" o.c. · 3112.2 Pa (65 psf) @ 24" o.c. · 2453.9 Pa (51.3 psf) @ 36" o.c. · 2384.3 Pa (49.8 psf) @ 48" o.c. (ASTM D5206-06A)
InstallationHorizontal / Vertical / Diagonal — screws every 16" to 48" o.c. in pre-punched holes
BackingPlywood min. 5/8" | Wood furring 16" o.c. | Metal furring 16" o.c. — all furring must be level horizontally and vertically

Vented version available: 4.594 sq.in. of ventilation per linear foot. S junction clip available for panel jointing at notched ends. TEXTURAL III & IV matte paint system. Mandatory end reinforcement fold for 24g & 26g panels (optional for 22g). Individual panel replacement possible without removing adjacent panels.

Versa - Versa Vented profile
VS-VVersa Vented

Ventilated version of the Versa panel for use as siding or soffit. Provides 4.594 sq.in. of ventilation per linear foot while maintaining the same wide-panel visual profile and installation system.

LengthCustom up to 12' (3658 mm)
Height / Width12" coverage (304.8 mm)
Thickness1" depth (25.4 mm)
Panel WeightSame as standard Versa (1.32 lb/ft² at 24g)
Panels/Box50 panels/box
CoverageDepends on custom length ordered
Wind ResistanceSame profile ratings as VS
InstallationHorizontal / Vertical / Diagonal — identical fastening to non-vented panel
BackingSame as standard Versa

Ventilation openings: 4.594 sq.in. per linear foot. Ideal for vented soffit applications maintaining the Versa aesthetic.

Certifications & Testing Standards

Versa meets or exceeds the following Canadian and international performance standards.

Test / PropertyStandardResult / Value
CAN/ULC-S135 — Fire Resistance, Non-Combustible Construction (Canada)
-Certified
ASTM E84 — Class A Fire Resistance (USA)
-Certified
NFPA — 0 Flammability Hazard Rating
-Certified
ASTM E2768 — Non-Combustible Construction for Wildland Urban Interface (WUI) in California
-Certified
W.U.I. Wildland Urban Interface Accreditation — Registration 8140-2358-0500
-Certified
ASTM D5206-06A — Wind Load: 3830.4 Pa (80 psf) @ 16" o.c. | 3112.2 Pa (65 psf) @ 24" o.c. | 2453.9 Pa (51.3 psf) @ 36" o.c. | 2384.3 Pa (49.8 psf) @ 48" o.c.
-Certified
ASTM E330 — Wind Deflection: +3100 / −3100 Pa @ 16" o.c. | +3000 / −3100 Pa @ 24" o.c.
-Certified
ASTM E283 — Air Leakage of Wall Assembly: Compliant
-Certified
ASTM B-117
-2000h — Corrosion Resistance Standard for MAC Screws
40-Year Limited Warranty — Paint Defects, Discoloration & Chalking
-Certified
LEED Recyclable —
-86% Recycled Content; 100% Recyclable at End of Life
FBC — Florida Building Code (Evaluation — in progress)
-Certified
TDI — Texas Department of Insurance (in progress)
-Certified
Miami Dade / ASTM E1886, E1996, TAS 202 & TAS 203 — ZHLA.63 Hurricane Resistance (not yet tested)
-Certified

Compatible Accessories

Installation Guide

  1. Versa panels have no visible screws or joints along their entire length. Panels fit together via a male/female clip system that accommodates thermal expansion — never force panels or screw through the face.

  2. End reinforcement fold is mandatory for 24g and 26g panels, optional for 22g. Before installing, use the MAC folding tool for Versa & Metal Block to fold panel ends at 90° (½" or 1" minimum) — prevents end deformation and panel separation.

  3. Install Starting Strip (M10G) 3½" above where the wall will start. Level carefully — it determines the straightness of the entire installation. Use MAC 1-1/2" flathead metal screws or 1-1/8" flathead wood screws. For vertical installation, install M50G drip molding at the base instead — no starter strip required.

  4. Drive screws every 16" to 48" o.c. in pre-punched holes with moderate pressure only. Screws must not exert upward or downward pressure on the panel — this causes deformation and joint spacing.

  5. Do NOT install over ZIP System Insulated R-Sheathing or similar dual-composite panels — insufficient rigidity causes movement, deformation, and oil canning under varying weather and sun exposure.

  6. Check alignment every 3–4 panels. Remove the protective film only after the panel is installed where possible — leaving it in place protects the finish during installation and allows visual inspection of alignment.

  7. For inside corners (M22G): slide panel end into molding leaving a 1/8" gap for expansion. For outside corners, install M20G (2-piece: secure strip with screws then apply MAC sealant inside finishing molding before stapling) or M21G (single-piece with inverted fold).

  8. For window openings: install J Trim (M01G) on both sides and bottom; install drip cap above. If the top panel doesn't reach full height, cut with extra ½" and create a 180° fold for additional support — install the cut panel backwards.

  9. Apply MAC sealant in the female clip in ½" × 1" strokes every 24" starting from the 4th floor on tall buildings, or from the 2nd floor in wind-exposed risk areas.

  10. For multi-storey wood structures: install horizontal expansion moldings at every floor. For steel structures or very long walls: install transition moldings every 30 ft.

  11. Cut panels using the MAC Guillotine designed for Versa and Metal Block, or with steel snips/shears. Electric saws and grinders are NOT covered by MAC warranty and may leave metal particles that accelerate corrosion.

  12. Notify your supplier before installing more than 500 sq. ft. if any product issue is discovered during installation to ensure warranty coverage is preserved.

Ready to order Versa?

Submit your spec list and we'll respond with pricing and availability - usually within one business day. Available in 9 colours for your project.

Get a wholesale quote

Tell us the product, colour, and quantity - we'll handle the rest.

Request a Quote
or call us at+1 (905) 836-7272