Skip to main content
Skip to main content
Exterior Pro Materials
MAC Metal ArchitecturalHarrywood Collection

Harrywood PLUS

Harrywood PLUS by MAC Metal Architectural is a pre-painted galvanized steel siding profile that delivers the warmth of natural wood without any of the maintenance. Its innovative serrated interlocking system eliminates exposed screws entirely — each panel simply drops onto the one below and locks with gravity. The TEXTURAL IV matte wood-grain paint system includes 6 unique plank variations per colour in every box, creating a truly natural, non-repetitive wall finish that blends with both contemporary and traditional architecture.

3/8" depth · 6 lbs/panel3750 Pa / 78 psf @ 16" o.c. wind10 colours

Available Colours

10
Harrywood PLUS - Ash Grey

Ash Grey

Wood Collection

Wood Collection(10)

Colours shown are approximate representations only and may appear differently on screen than the actual product. Request a physical sample before making your final decision.

Profiles & Specifications

Harrywood PLUS - Harrywood PLUS profile
HWPHarrywood PLUS

Prefinished galvanized steel wall profile with serrated interlocking system and no exposed screws. Each panel seats on top of the next using gravity and a gentle push — no special tools needed to lock panels.

Length144" (3658 mm)
Height / Width6.0625" exposure (154 mm)
Thickness3/8" depth (9.5 mm)
Panel Weight6 lbs/panel (2.7 kg) · 78 lbs/box 26g | 98 lbs/box 24g
Panels/Box12 panels/box
Coverage72.75 sq.ft./box (6.75 m²)
Wind Resistance3750 Pa (78 psf) @ 16" o.c. · 3030 Pa (63 psf) @ 24" o.c. (ASTM D5206-06A)
InstallationHorizontal / Vertical / Diagonal — screws every 16" or 24" o.c. in pre-punched slots
BackingPlywood min. 5/8" | Wood furring 16" or 24" o.c. | Metal furring 16" or 24" o.c. — all furring must be level

TEXTURAL IV paint system — matte wood-grain finish reproducing real wood texture. Wood Collection: 6 plank variations per colour; install in random order (numbered on back) to avoid wallpaper effect.

Harrywood PLUS - Harrywood PLUS Vented profile
HWP-VHarrywood PLUS Vented

Ventilated version of the Harrywood PLUS panel for use as siding or soffit. Provides 4.94 sq. in. of ventilation per linear foot of profile while maintaining the same visual profile.

Length144" (3658 mm)
Height / Width6.0625" exposure (154 mm)
Thickness3/8" depth (9.5 mm)
Panel Weight6 lbs/panel (2.7 kg)
Panels/Box12 panels/box
Coverage72.75 sq.ft./box (6.75 m²)
Wind ResistanceSame profile ratings as HWP
InstallationHorizontal / Vertical / Diagonal — identical fastening to non-vented panel
BackingFurring at 16" o.c. when installed as soffit, parallel or perpendicular to wall

Ventilation openings must be folded down at panel ends for parallel-to-wall soffit joints. Use 3/8" engineered wood block at joints for a seamless appearance.

Certifications & Testing Standards

Harrywood PLUS meets or exceeds the following Canadian and international performance standards.

Test / PropertyStandardResult / Value
CAN/ULC-S135 — Fire Resistance, Non-Combustible Construction (Canada)
-Certified
ASTM E84 — Class A Fire Resistance (USA)
-Certified
NFPA — 0 Flammability Hazard Rating
-Certified
W.U.I. Wildland Urban Interface Accreditation — Registration 8140-2358-0500
-Certified
ASTM D5206-06A — Wind Load: 3750 Pa (78 psf) @ 16" o.c. | 3030 Pa (63 psf) @ 24" o.c.
-Certified
ASTM E330 — Wind Deflection: ±3100 Pa @ 16" o.c. | +3000 / -3100 Pa @ 24" o.c.
-Certified
ASTM E283 — Air Leakage of Wall Assembly: Compliant
-Certified
TDI EC-150 — Texas Department of Insurance Evaluation
-Certified
ASTM B-117
-2000h — Corrosion Resistance Standard for MAC Screws
40-Year Limited Warranty — Paint Defects, Discoloration & Chalking
-Certified
LEED Recyclable —
-86% Recycled Content; 100% Recyclable at End of Life

Compatible Accessories

Installation Guide

  1. Wood Collection panels come in 6 plank variations per colour (numbered on the back). Install in random order — never repeat the same sequence to avoid a wallpaper effect.

  2. Store panels indoors in a dry, well-ventilated area. If outdoor storage is necessary, keep flat and away from direct sunlight or extreme temperatures to prevent protective film from bonding to panels.

  3. Do NOT install over ZIP System Insulated R-Sheathing or similar soft dual-composite panels — insufficient rigidity causes warping and oil canning under sun exposure.

  4. Install Starting Strip (M10SHW) first, perfectly level, 3" above the base of the wall. Use a laser or chalk line for accuracy — this strip guides every row above it.

  5. Drive screws every 16" or 24" o.c. in the centre of pre-punched slots with moderate contact only — do not overtighten. Screws must allow the steel to expand and must not exert upward or downward pressure on the panel.

  6. Remove the factory protective film from panels before installation to allow visual inspection as work progresses.

  7. Check alignment every 3–4 panels. If furring is not perfectly aligned, leave a slight gap under the panel rather than forcing it to avoid tension and warping.

  8. Leave 1/8"–1/4" expansion gap between panel lengths at all cross joints. On walls over 30 ft., install vertical expansion molding; on multi-storey structures, install horizontal transition molding at every floor.

  9. Cut panels using the MAC Harrywood PLUS cutter, sheet metal scissors, or steel nibbler only. Hot cutting or circular/angle grinders leave residual hot metal particles that damage the factory finish and void the warranty.

  10. Notify your supplier before installing more than 144 sq. ft. (2 boxes) if any product issue is discovered during installation to ensure warranty coverage is preserved.

Ready to order Harrywood PLUS?

Submit your spec list and we'll respond with pricing and availability - usually within one business day. Available in 10 colours for your project.

Get a wholesale quote

Tell us the product, colour, and quantity - we'll handle the rest.

Request a Quote
or call us at+1 (905) 836-7272